Home / News
  • 01 Apr’ 2025
    Does the surface box allow for quick wiring and connections?

    Surface boxes can indeed achieve fast wiring and connection. Its design makes the wiring process simple and efficient. Unlike traditional embedded socket installation methods, surface boxes do not require large holes in the wall. They only need to be fixed on the wall surface, and then the cables are connected through the openings on the box. This installation method avoids the trouble of wall damage and reduces the time consumption during installation. Due to the fact that surface boxes typically have multiple ports, they can accommodate different connection points such as power sockets and data outlets simultaneously, allowing users to complete various wiring tasks in one stop.In addition, the design of the surface box makes cables and connectors easier to access and operate, making it easier to maintain, upgrade, or adjust connections in the future. For situations that require temporary wiring or frequent changes in wiring, surface boxes are particularly suitable because they do not rely on the fixed structure of the wall and can be easily moved or reinstalled, quickly adapting to different wiring needs. Therefore, in situations where rapid wiring, connection, and adjustment are required, surface boxes are a very efficient choice.

  • 24 Mar’ 2025
    Is the surface box suitable for installation in places where it needs to be moved?

    Surface boxes are suitable for installation in situations that require movement to a certain extent, but their specific applicability needs to be analyzed based on the situation and requirements.Surface box usually refers to a junction box or installation box installed on a surface (such as a wall, tabletop, etc.), used to accommodate and fix electrical or communication modules, sockets, switches, and other equipment. The flexibility and ease of installation of surface boxes make them a viable option in situations that require movement, such as office desks, raised floors, or doors and windows.For example, installing a surface box on the desk can conveniently provide power, network interfaces, etc., to meet the electricity and communication needs of office equipment. Meanwhile, as the position and layout of the office desk may be adjusted as needed, the installation method of the surface box also allows it to move with the movement of the desk, thereby maintaining the continuity of electrical and communication connections.However, in situations where frequent movement or significant mechanical stress is required, the stability and durability of the surface box may be challenged. In these cases, it is necessary to choose installation methods and materials with higher strength and stability to ensure the normal operation and safety of the surface box and its internal equipment.In addition, it is necessary to consider the waterproof and dustproof performance of the surface box to ensure its reliability and durability in different environments. Especially in humid, dusty, or corrosive environments, it is necessary to choose surface boxes with corresponding protection levels to avoid damage to internal equipment.

  • 18 Mar’ 2025
    Do I need to drill a hole when installing the surface box?

    When installing surface boxes, it is usually not necessary to make large holes in the wall. Its design is to avoid being embedded in the wall, so it can be directly fixed on the surface of the wall. The installation process mainly involves fixing the surface box to the wall, usually using screws to connect the box to the wall. Small holes need to be drilled on the wall to install fixing screws, instead of opening a larger hole like traditional sockets to fit into the box or socket.When the wall is made of hard materials such as concrete or brick walls, it may be necessary to use expansion screws or other specialized fixing tools to ensure that the surface box is securely installed. For wooden walls, ordinary screws can be used. After installing the surface box, wires or data cables are connected to sockets, jacks, and other devices through the openings on the box. Due to its avoidance of wall damage, this installation method is particularly suitable for temporary installations, renting space, or situations where connection points cannot be installed inside the wall.In general, there is no need to cut the wall when installing the surface box. Only small holes need to be drilled to fix the screws, making it stable on the surface. The installation process is relatively simple and does not damage the wall.

  • 12 Mar’ 2025
    How to improve the transmission speed of enterprise network through CAT5E/CAT6 Shielded Pass-Through Module?

    1. Optimize network transmission performance: support up to 250MHz frequencyCAT5E/CAT6 Shielded Pass-Through Module supports up to 250MHz transmission frequency, which is one of the key factors to improve the transmission speed of enterprise network. Enterprise network usually needs to carry a large amount of data traffic, especially in high bandwidth demand application scenarios such as HD video conferencing, big data processing and cloud computing. The higher the frequency, the more data can be transmitted per unit time, which directly improves the overall bandwidth and data transmission speed of the network. 2. Reduce near-end crosstalk (NEXT): ensure signal qualityIn enterprise network, signal quality is another key factor to ensure high-speed transmission. CAT5E/CAT6 Shielded Pass-Through Module has a built-in circuit board (PCB) and adopts advanced crosstalk compensation technology to significantly reduce near-end crosstalk (NEXT). Crosstalk refers to the signal loss caused by electromagnetic interference between wire pairs during signal transmission. Especially at high-speed transmission, the crosstalk problem will be more serious, affecting the stability and transmission speed of the network. The module optimizes crosstalk compensation through a built-in circuit board, reduces the impact of interference sources on the signal, and ensures that the quality of the signal is not lost during transmission. Therefore, deploying CAT5E/CAT6 Shielded Pass-Through Module in the enterprise network can effectively improve the clarity of the signal, reduce packet loss and retransmission, and thus improve the transmission speed of the overall network. 3. Anti-interference ability: improve transmission stabilityEnterprise networks are usually faced with various electromagnetic interference (EMI), especially in data centers or office environments with many devices. External electromagnetic interference may have a negative impact on network signals and reduce transmission speed. CAT5E/CAT6 Shielded Pass-Through Module adopts a shielded design (Shielded), that is, a metal shielding layer is added between the module housing and the line to effectively reduce the impact of external electromagnetic interference on the signal. 4. Improve the reliability and durability of network connectionsThe stability of the enterprise network not only depends on the transmission speed, but is also closely related to the reliability of network equipment. CAT5E/CAT6 Shielded Pass-Through Module uses high-hardness phosphor copper material and nickel-gold process for the contact part, so that the module maintains low contact resistance in long-term use and reduces signal loss caused by poor contact or oxidation. The plug-in and unplug life of the module exceeds 801 times, which means that in high-frequency plug-in and unplug operations, the module can maintain high stability and avoid network instability caused by frequent plug-in and unplug. Therefore, enterprises use this module in network construction, which can not only improve data transmission speed, but also ensure long-term stable operation of network connection, avoid frequent maintenance and fault repair, and improve the reliability and durability of the overall network. 5. Support Gigabit Ethernet: Improve bandwidth capacityWith the increasing demand for bandwidth in network applications, Gigabit Ethernet has become a standard in enterprise network construction. CAT5E/CAT6 Shielded Pass-Through Module fully complies with the Gigabit Ethernet standard and can support transmission rates up to 1000Mbps, which enables enterprises to increase the bandwidth of existing networks without adding additional network equipment and meet applications with high-frequency bandwidth requirements.

  • 05 Mar’ 2025
    Why does CAT5E/CAT6 Shielded Pass-Through Module support transmission frequencies up to 250MHz?

    1. The role of built-in circuit board (PCB)The CAT5E/CAT6 Shielded Pass-Through Module integrates a circuit board, which is a very critical design. The main function of the circuit board is to improve near-end crosstalk, that is, when data is transmitted through the network cable, signal interference may occur between different lines. The circuit board of this module adopts efficient crosstalk compensation technology, which effectively reduces signal loss and transmission errors caused by electromagnetic interference. Therefore, the module can support frequencies up to 250MHz and maintain the stability of data transmission. 2. Selection of high-hardness phosphor copper contact partsCAT5E/CAT6 Shielded Pass-Through Module uses high-hardness phosphor copper as the material of the contact part, and is plated by nickel-gold process. Phosphor copper material has excellent conductivity, wear resistance and corrosion resistance, so it can reduce contact resistance and ensure efficient signal transmission. The use of nickel-gold process not only increases the durability of the contact points, but also reduces the signal attenuation caused by oxidation and corrosion, and improves the durability and stability of the module. These features enable the module to perform efficient data transmission at a higher frequency, support the frequency requirement of 250MHz, and at the same time extend the service life of the module and reduce maintenance costs. 3. Design to support Gigabit EthernetThe design of CAT5E/CAT6 Shielded Pass-Through Module meets the requirements of Gigabit Ethernet and can support high-speed transmission of 1000Mbps. To achieve this goal, the module must have a higher transmission frequency and low crosstalk performance. According to the standard, the frequency requirement of Gigabit Ethernet network is usually 250MHz, and this module achieves this goal by adopting advanced crosstalk compensation circuits, high-quality materials and sophisticated process design. Supporting the transmission frequency of 250MHz is to ensure that the network can stably transmit large amounts of data, especially in high-bandwidth demand occasions such as data centers, enterprise networks and high-speed Internet access. This enables CAT5E/CAT6 Shielded Pass-Through Module to provide high-speed and stable data connections in various network environments. 4. Anti-interference capability and shielding designThe module adopts a shielding design, that is, a metal shielding layer is added between the module housing and the line to reduce external electromagnetic interference. Electromagnetic interference is one of the main factors affecting the stability of high-speed networks, especially in high-frequency transmission, the signal is easily interfered by external electromagnetic waves. 5. Plug-in life and reliabilityThe plug-in life of the CAT5E/CAT6 Shielded Pass-Through Module reaches more than 800 times, which means that the module can withstand frequent plug-in and plug-out use and maintain excellent performance for a long time. This feature is very important because transmission at high frequencies requires higher contact stability and reliability.

  • 26 Feb’ 2025
    Uniqueness of 24-Port Unshielded Wiring Rack Cold-rolled Steel Plate Frame

    1. Superiority of Cold-rolled Steel Plate MaterialAs a high-quality metal material, cold-rolled steel plate has been widely used in many industrial fields for its high strength, good ductility and corrosion resistance. In 24-Port Unshielded Wiring Rack, cold-rolled steel plate is used as the main material of the frame, which is mainly due to its following characteristics: High strength: cold-rolled steel plate has higher strength and hardness than hot-rolled steel plate after cold processing. This enables the frame of the patch panel to withstand greater external forces and ensure stability in complex and changing network environments.Good ductility: cold-rolled steel plate maintains good ductility during processing, which enables the frame to easily adapt to various shapes and sizes during the manufacturing process, while ensuring the stability and reliability of the frame in long-term use.Corrosion resistance: cold-rolled steel plate has been specially treated and has good corrosion resistance. In humid environments such as data centers, this corrosion resistance ensures that the frame of the patch panel is not easy to rust and corrode, extending its service life.2. Design advantages of one-piece frameThe cold-rolled steel plate frame of 24-Port Unshielded Wiring Rack adopts one-piece design, which brings many advantages: Stable structure: The one-piece frame is more stable in structure and can withstand greater loads, ensuring the stability and safety of the patch panel in network cabling.Easy installation: The one-piece design simplifies the installation process, reduces the parts and connection points required for installation, and reduces the difficulty and time cost of installation.Beautiful: The one-piece frame has a simple and smooth appearance, which meets the aesthetic needs of modern data centers and also enhances the professional image of the entire wiring system.3. Load-bearing and tensile bearing capacity of the frameAs a key component of the network cabling system, the frame of the patch panel needs to be able to withstand the tension from the wire clamps and cables. The cold-rolled steel plate frame of 24-Port Unshielded Wiring Rack shows excellent performance in this regard: High-strength load-bearing: The high-strength characteristics of cold-rolled steel plates enable the frame to withstand greater weight, ensuring that the structure will not be deformed or damaged due to weight problems in network cabling.Excellent tensile bearing capacity: The design of the frame fully considers the tensile force of the wire clamp and cable on the frame. Through reasonable structural layout and material selection, it ensures that the frame can withstand this tensile force without deformation or breakage during long-term use.4. Heat dissipation and electromagnetic shielding performance of the frameAlthough the design focus of the 24-Port Unshielded Wiring Rack is on wiring management, the cold-rolled steel plate frame also shows certain advantages in heat dissipation and electromagnetic shielding: Heat dissipation performance: The cold-rolled steel plate has good thermal conductivity, so that the frame can assist in heat dissipation to a certain extent, reduce the temperature inside the patch panel, and improve the stability and service life of the equipment.Electromagnetic shielding: Although the patch panel is unshielded, the cold-rolled steel plate frame itself has a certain electromagnetic shielding capability, which can reduce the impact of electromagnetic interference on network wiring to a certain extent.

  • 19 Feb’ 2025
    How to use 24-Port Unshielded Wiring Rack to achieve efficient network cabling management?

    1. Rugged and durable design24-Port Unshielded Wiring Rack adopts a thickened cold-rolled steel plate one-piece frame. This design not only makes it simple and elegant, but more importantly, ensures the durability of the patch panel. This material and process enable the patch panel to easily withstand the tension between the wire clamps and maintain stable performance even in a busy network environment. 2. Clear label managementFor network cabling management, clear labeling is crucial. 24-Port Unshielded Wiring Rack is equipped with a removable cover, which makes it very convenient to replace and manage cable labels. By affixing clear and concise labels to each cable, administrators can understand the purpose and destination of each cable at a glance, thereby greatly improving the efficiency of cabling management. 3. Flexible configuration options24-Port Unshielded Wiring Rack provides 24 ports to meet the needs of network cabling of different sizes. At the same time, it also supports DIY assembly, and can freely combine components such as wire clips, modules, etc. of different specifications and types according to actual needs. 4. Wide compatibilityIn network cabling, compatibility is an issue that cannot be ignored. 24-Port Unshielded Wiring Rack is compatible with shielded/unshielded/free modules, which means it can be used with many different types of cables and devices. 5. Efficient network cabling practiceIn actual applications, the following steps can be followed to manage network cabling using 24-Port Unshielded Wiring Rack:Plan the network topology: First, it is necessary to plan the network topology according to actual needs and network scale, and determine the purpose of each port and the connected devices.Install the patch panel: According to the planning results, install the 24-Port Unshielded Wiring Rack in a suitable location, and ensure that it is firmly fixed and reliably connected.Arrange cables: Arrange and connect cables according to the planning results and actual needs. During the connection process, pay attention to keeping the cables neat and orderly, and avoid crossing and entanglement.Affix labels: Affix clear and concise labels to each cable to indicate its purpose and destination. This helps administrators quickly identify and manage cables.Perform testing and optimization: After completing the cabling, testing is required to ensure the stability and reliability of the network. At the same time, the cabling is optimized and adjusted according to the test results to improve the performance and efficiency of the network.

  • 12 Feb’ 2025
    How does the built-in PCB of CAT5E/CAT6 Unshielded Pass-Through Module improve NEXT?

    1. Principle of PCB design to improve NEXTThe main role of PCB in CAT5E/CAT6 Unshielded Pass-Through Module is to provide an orderly electrical path to reduce mutual interference of signals during transmission. In the network cable, each pair of wires is arranged with a specific twist rate and spacing to reduce NEXT. However, at the connection end, such as the RJ45 interface, these wire pairs need to be separated in order to be inserted into the interface. At this time, the design of PCB is particularly important. PCB ensures that each signal path has sufficient isolation through precise layout and routing, thereby reducing crosstalk between wire pairs. Specifically, the signal lines on the PCB are designed to a specific width and spacing to match the electrical characteristics of the network cable. In addition, the PCB also uses impedance matching technology to ensure the integrity of the signal during transmission. 2. How PCB Enhances Signal IntegrityIn CAT5E/CAT6 Unshielded Pass-Through Module, PCB not only improves signal quality by reducing NEXT, but also improves overall network performance by enhancing signal integrity. Signal integrity refers to the ability of a signal to maintain its original waveform and amplitude during transmission. To achieve this goal, PCB uses a variety of technologies: Impedance control: The signal lines on the PCB are designed to have specific impedance values ​​to match the impedance of the network cable. This impedance matching reduces signal reflection and distortion, thereby improving signal integrity.Ground plane design: PCBs typically contain one or more ground planes that provide a low-impedance return path for the signal. This helps reduce electromagnetic interference (EMI) and radio frequency interference (RFI), further protecting signal integrity.Decoupling capacitors: On PCBs, decoupling capacitors are used to stabilize the power supply voltage and reduce the impact of power supply noise on the signal. This helps improve signal stability and clarity.3. Combining the advantages of CAT5E/CAT6 network cable characteristicsCAT5E and CAT6 network cables support Gigabit and 10 Gigabit Ethernet transmission, respectively, and have different electrical and mechanical characteristics. CAT5E network cable has a maximum bandwidth of 100MHz and supports 1000BASE-T transmission; while CAT6 network cable has a higher bandwidth (250MHz) and supports 10GBASE-T transmission. In the CAT5E/CAT6 Unshielded Pass-Through Module, the design of the built-in PCB fully considers these characteristics: Compatibility: The design of the PCB ensures that the module is compatible with CAT5E and CAT6 network cables and can be used on network cables of different specifications without modification.Performance improvement: By optimizing NEXT and enhancing signal integrity, the PCB enables the CAT5E/CAT6 Unshielded Pass-Through Module to fully realize the performance potential of the network cable, especially in high-speed data transmission environments.Reliability enhancement: The precise design and manufacturing process of the PCB improves the reliability and durability of the module and reduces network failures caused by poor connections or signal interference.

  • 05 Feb’ 2025
    What are the advantages of the RJ45 interface of CAT5E/CAT6 Unshielded Pass-Through Module?

    1. Standardized high-speed transmission interfaceThe RJ45 interface, full name Registered Jack 45, is the most common connection interface in Ethernet networks. It follows the IEEE 802.3 standard and supports multiple Ethernet transmission standards such as 10BASE-T, 100BASE-TX, 1000BASE-T and 10GBASE-T. In the CAT5E/CAT6 Unshielded Pass-Through Module, the RJ45 interface ensures that data can be transmitted at Gigabit (CAT5E) or even 10 Gigabit (CAT6). 2. Compatibility and flexibilityAnother significant advantage of the RJ45 interface is its wide compatibility. Whether it is CAT5E or CAT6 network cable, it can be connected to various network devices (such as computers, routers, switches, etc.) through the RJ45 interface. In addition, CAT6 network cables are also backward compatible with CAT5E and earlier network cable specifications, which means that users do not need to worry about compatibility issues after equipment upgrades. In the CAT5E/CAT6 Unshielded Pass-Through Module, the compatibility of the RJ45 interface ensures that users can flexibly choose and use network cables of different specifications to meet network requirements in different scenarios. 3. Excellent anti-interference performanceIn a complex electromagnetic environment, anti-interference performance is one of the important indicators for measuring the quality of network interfaces. Although the CAT5E/CAT6 Unshielded Pass-Through Module uses a twisted pair structure to reduce signal interference, its stability may be affected to a certain extent in a high electromagnetic interference environment. The CAT6 network cable uses better shielding technology, such as metal foil shielding and braided layers, to provide higher anti-interference performance. In the CAT5E/CAT6 Unshielded Pass-Through Module, the RJ45 interface ensures good contact and shielding effect between the network cable and the interface through precise design and manufacturing processes, thereby further improving the anti-interference performance of the entire network connection. 4. Easy to install and maintainThe design of the RJ45 interface makes the installation and maintenance of the network cable easier and faster. In the CAT5E/CAT6 Unshielded Pass-Through Module, users only need to insert the network cable into the RJ45 interface and fix it with a crimping tool. This stripping-free design not only saves installation time, but also reduces the difficulty of operation. At the same time, the modular design of the RJ45 interface allows users to easily replace damaged network cables or interfaces, thereby improving the maintainability of the entire network system. 5. Adapt to a variety of application scenariosThe RJ45 interface in the CAT5E/CAT6 Unshielded Pass-Through Module adapts to the needs of a variety of application scenarios with its high-speed transmission, wide compatibility, excellent anti-interference performance, and easy installation and maintenance. Whether it is a high-performance network environment such as a home network, office network, or data center, the RJ45 interface can provide a stable and reliable network connection. Especially in network environments that require higher bandwidth and speed, such as enterprise networks, video surveillance networks, etc., the use of CAT6 network cables with RJ45 interfaces will bring better network performance.

  • 29 Jan’ 2025
    Why does CAT6/CAT6a Unshielded LED Light Module use gold-plated pins?

    1. Gold-plated pins improve electrical performanceIn network connections, the conductivity of the pins directly affects the stability and speed of data transmission. Gold is an excellent conductive material that provides extremely low resistance, making the current conduction smoother at the connection. CAT6/CAT6a Unshielded LED Light Module uses gold-plated pins to ensure better conductivity. This is especially important for high-frequency data transmission, because during high-speed transmission, excessive contact resistance may cause signal attenuation, data packet loss, and even connection interruption. 2. Gold-plated pins improve corrosion resistanceOver time, metal materials may corrode due to oxidation or other chemical reactions. For network connection components, corrosion can cause poor contact and obstruction of current flow, thereby affecting the stability of network connections. Gold has excellent corrosion resistance and hardly oxidizes or rusts in the air. Therefore, CAT6/CAT6a Unshielded LED Light Module uses gold plating on its pins to effectively avoid poor electrical contact problems caused by corrosion. 3. Gold-plated pins improve durability and plug-in timesGold-plated pins show excellent durability in frequent plug-in and plug-out scenarios. Network equipment connections usually require multiple plug-in and plug-out operations, especially during network installation, maintenance or replacement. If the pin material is not durable enough, problems such as poor contact and signal loss may occur after long-term use. However, gold plating has high wear resistance and durability, and can maintain its surface integrity and conductivity even after multiple plug-ins. CAT6/CAT6a Unshielded LED Light Module uses gold-plated pins to ensure that the module can maintain stable electrical connection and signal transmission even in an environment with frequent plug-in and plug-out. This design greatly improves the service life of the equipment, avoids network failures caused by metal fatigue, and ensures stability in long-term use. 4. Gold-plated pins ensure connection stability and reliabilityThe stability of network connections depends not only on the transmission medium, but also on the quality of the connection points. Gold-plated pins have very low contact resistance, which minimizes interference and loss during signal transmission. This is crucial for CAT6/CAT6a Unshielded LED Light Module, especially in high-speed data transmission and high-frequency applications, where any minor connection problems may lead to network instability. Gold-plated pins ensure low loss and high efficiency during signal transmission, ensuring that the module can maintain a stable connection in a high-speed, high-load network environment. Whether in a data center, a high-frequency enterprise network, or a home network, the excellent electrical properties of gold plating can effectively avoid the problem of unstable connection and improve the reliability of the entire system. 5. Advantages of gold-plated pins in environmental adaptabilityCAT6/CAT6a Unshielded LED Light Module is widely used in a variety of network environments, from high-temperature, high-humidity industrial environments to home or office environments with large temperature changes. Gold plating not only improves the conductivity of the pins, but also enhances their adaptability to environmental changes. The oxidation resistance and corrosion resistance of gold enable the module to work stably under various harsh conditions without being easily affected by moisture, oxides or other harmful substances in the air.

  • 22 Jan’ 2025
    How does CAT6/CAT6a Unshielded LED Light Module achieve better electrical connection performance?

    1. Use high-quality gold-plated pins to optimize electrical contact performanceThe quality of electrical connection is directly related to the stability and speed of signal transmission. In CAT6/CAT6a Unshielded LED Light Module, the pins are designed with gold plating, which is an important part of improving electrical connection performance. As a metal with excellent conductivity, gold can provide low-resistance contact points, effectively reducing loss and interference during signal transmission. Gold-plated pins not only improve conductivity, but also greatly reduce contact resistance, which is especially important for high-speed data transmission. During high-speed transmission, if the contact is poor or the resistance is too high, the signal will be seriously affected, and may even cause data loss or network interruption. The use of gold plating enables the module to always maintain a stable electrical connection in a complex environment, thereby ensuring the reliability and efficiency of the network system. 2. Optimized metal materials and corrosion-resistant designIn addition to gold plating, CAT6/CAT6a Unshielded LED Light Module also uses a combination of phosphor bronze and nickel plating. This design ensures the stability of the IDC (insulation displacement contact) port in long-term use and prevents poor electrical contact caused by corrosion. The choice of phosphor bronze material has excellent elasticity and good conductivity, while the nickel plating enhances corrosion resistance, allowing the module to operate stably in harsh environments such as moisture and salt spray. 3. Accurate LED indication function to improve ease of useIn order to further enhance the user experience, the CAT6/CAT6a Unshielded LED Light Module also integrates an LED indication function. This design not only has a visual prompt function, but also helps users detect the status of line connections in real time. The on or off of the LED light clearly indicates the electrical connection of the module, thereby greatly improving the convenience and accuracy of cable connection. The addition of LED indicators can also help operation and maintenance personnel locate fault points more efficiently and diagnose problems quickly during network maintenance. For network environments that require high availability and high stability, the LED indication function provides higher visibility and ease of operation for electrical connection performance. 4. PC plastic shell design to improve electrical isolation performanceThe plastic shell of CAT6/CAT6a Unshielded LED Light Module adopts PC (polycarbonate) injection molding technology. This material meets international standards and has stronger impact resistance, thermal stability and better electrical isolation performance. The shell can not only effectively avoid external electromagnetic interference, but also prevent the static electricity generated during the network connection from affecting the electrical connection performance. High-quality PC shells also have good flame retardant properties, which is essential to avoid the risk of fire caused by overheating or short circuits. Through this shell design, CAT6/CAT6a Unshielded LED Light Module can enhance the safety of the overall system while ensuring electrical connection.

  • 15 Jan’ 2025
    How does CAT6/CAT6a Unshielded LED Light Module improve the stability of network connection?

    1. Strictly comply with international standards to ensure connection qualityCAT6/CAT6a Unshielded LED Light Module strictly follows international standards ISO/IEC 11801 and TIA/EIA 568 during design and production. These standards have extremely high requirements for the quality of network connection, covering electrical characteristics, data transmission rate, transmission distance and other aspects. The module meets these standards, ensuring the stability of network connection, being able to withstand high-intensity data transmission requirements, and avoiding network instability caused by signal interference or poor connection. 2. LED indication function, real-time detection of connection statusCAT6/CAT6a Unshielded LED Light Module is equipped with LED indication function, which is one of its highlights. The LED light will indicate the connection status of the line in real time during operation. When there is poor contact or connection problem, the LED indicator can reflect it intuitively. Users can quickly find problems and troubleshoot them, avoiding network interruption or performance degradation caused by problems not being discovered in time in traditional connection methods. 3. Phosphor copper and nickel plating design to improve connection stabilityThe pins of the module are designed with phosphor copper and nickel plating. This material combination not only ensures good electrical conductivity, but also effectively resists corrosion. During long-term use, traditional materials may cause poor contact due to oxidation or corrosion, thus affecting the stability of network connection. However, the combination of phosphor copper and nickel plating enhances the module's antioxidant and corrosion resistance, ensures the stability of IDC technology, and thus maintains a continuous and reliable electrical connection. 4. Gold-plated pins to ensure efficient data transmissionIn order to further improve the stability of the connection, the 8 pins of the CAT6/CAT6a Unshielded LED Light Module are treated with gold plating. The gold plating has excellent conductivity and corrosion resistance, which can effectively reduce the contact impedance and ensure that the data is not disturbed during transmission. The gold plating not only improves the electrical performance of the module, but also extends its service life. 5. PC injection molding, with good fire resistanceThe plastic shell of the module adopts PC injection molding technology, which meets international standards for fire resistance. This means that even in the case of high temperature or short circuit, the module can effectively avoid the risk of fire caused by overheating. PC plastic material not only has good impact resistance, but also can withstand high temperature changes, and can maintain stable working conditions in various harsh environments. 6. Applicable to a variety of network scenariosCAT6/CAT6a Unshielded LED Light Module is not only suitable for data centers and office environments, but also for home network wiring. In home decoration, smart home and small office network deployment, the module can provide a stable network connection to ensure the smooth operation of high-speed Internet, video streaming and other network applications. Whether it is for remote office or entertainment purposes, a stable network connection is the basis for ensuring the user experience, and the module can provide a stable and efficient network infrastructure with its excellent performance.