Home / News
  • 11 Sep’ 2024
    Cost-effectiveness and performance considerations of Unshielded Modules in data center construction: Why is it worth choosing?

    The advantages of Unshielded Modules in construction costs are mainly reflected in material costs and installation costs. Compared with shielded modules or cabling systems, unshielded versions are usually more economical. UTP cabling system is a typical example. Its material cost is much lower than the equivalent shielded twisted pair (STP), and the installation process is simpler, without the need for complex shield connection and grounding, thus reducing the overall construction cost.In the operation stage, Unshielded Modules also show cost advantages. Due to the relatively simple structure, the maintenance cost of unshielded modules or systems is low, and the failure rate is relatively low. In addition, although the energy consumption of data centers mainly comes from servers, storage devices, cooling systems, etc., the use of high-efficiency unshielded cabling systems can still help reduce energy costs to a certain extent, especially when deployed on a large scale.The performance of Unshielded Modules in transmission performance depends on the specific application scenario. In a data center with a relatively clean electromagnetic environment, unshielded cabling systems such as UTP can provide transmission performance comparable to that of shielded systems to meet the needs of high-speed data transmission. However, in an environment with strong electromagnetic interference, the performance of unshielded modules or systems may be affected, and additional anti-interference measures need to be taken.The rise of modular data center architecture has enabled Unshielded Module to show advantages in scalability and flexibility. These modules can be quickly deployed and expanded according to the needs of the data center without worrying about complex shielding layer connection issues. In addition, unshielded modules are usually lighter and smaller in size, which is convenient for transportation and installation, further improving the flexibility and responsiveness of the data center.When selecting Unshielded Module in data center construction, multiple factors need to be considered comprehensively. First, the electromagnetic environment of the data center should be evaluated to determine whether shielding measures are needed to ensure transmission performance. Secondly, the cost-effectiveness ratio should be considered, weighing the relationship between construction costs and long-term operating costs. Finally, attention should also be paid to the scalability and flexibility of the module or system to ensure that the data center can adapt to the needs of future business development.

  • 11 Sep’ 2024
    What precautions should be taken when installing and maintaining the Cat5e/Cat6 short-body unshielded module?

    When building or upgrading modern network systems, Cat5e and Cat6 short-body unshielded modules are popular for their compact design and wide compatibility. These modules not only help optimize wiring space, but also ensure high-speed and stable data transmission. However, to ensure that these modules can perform at their best, correct installation and regular maintenance are essential. Here are some precautions for the installation and maintenance of Cat5e/Cat6 short-body unshielded modules. Installation precautions1. Environmental preparation: Ensure that the installation environment is clean and dry to avoid dust, moisture and corrosive substances from damaging the module.Check whether the installation location meets the network wiring specifications and avoid electromagnetic interference sources such as high-power electrical appliances or radio transmission equipment.2. Choose the right tools: Use professional network crimping pliers and network testers to make and test network cables to ensure connection quality.Make sure all tools are qualified products to avoid using inferior tools that may cause damage to the network cable or poor contact.3. Correctly install the module: Install according to the module manual and wiring diagram to ensure that the module is correctly fixed on the panel or patch panel.Pay attention to the orientation and position of the module port to ensure that the network cable can be inserted smoothly and is not easy to loosen.Use the correct type of network cable (such as UTP or STP) and insert it into the corresponding position of the module strictly according to the color coding.4. Check the connection quality:After installation, use a network tester to detect the performance parameters such as connectivity, attenuation and crosstalk of each network cable.Ensure that all connection points are tightened reliably without looseness or poor contact.Maintenance precautions1. Regular inspection:Regularly (such as quarterly or semi-annual) check the physical state of the module and network cable, including whether there is wear, breakage or corrosion.Check whether the module fixings are loose or damaged, and adjust or replace them in time.2. Cleaning and maintenance:Use a clean cloth or cotton swab to gently wipe the module port and network cable plug to remove dust and dirt.Avoid using wet cloth or chemical cleaners to avoid damaging the module or network cable.3. Pay attention to temperature changes:Ensure that the module is installed within the appropriate temperature range to avoid excessively high or low temperatures affecting the module performance.If the module is installed outdoors or in an environment with large temperature changes, appropriate insulation or heat dissipation measures should be taken.4. Avoid excessive plugging and unplugging: Try to reduce the number of plugging and unplugging of the network cable to avoid damaging the port or plug.If you need to change the network cable frequently, make sure that the plugging and unplugging actions are gentle and accurate to avoid damage caused by excessive force.5. Repair faults in time: Once a fault is found in the module or network cable (such as failure to connect, slow data transmission, etc.), it should be checked and repaired immediately.If the fault cannot be solved by yourself, you should contact professional maintenance personnel in time for processing.

  • 11 Sep’ 2024
    What are the main technical features of Tool-Free Shielding Crystal Plug?

    In the era of rapid development of the Internet, efficient and stable network connections have become an indispensable infrastructure for all walks of life. In order to meet this demand, the field of network hardware continues to innovate, among which Tool-Free Shielding Crystal Plug is gradually becoming a new favorite in the field of network cabling and maintenance with its unique technical features. This article will explore the main technical features of Tool-Free Shielding Crystal Plug in depth and reveal how it reshapes the new pattern of network connection. No tools required, simplified installationThe most eye-catching technical feature of Tool-Free Shielding Crystal Plug is its tool-free design. The installation of traditional crystal plugs often requires tools such as screwdrivers or crimping pliers, which is not only cumbersome to operate, but also increases the error rate and time cost during the installation process. The Tool-Free Shielding Crystal Plug completely subverts this tradition. Users can easily complete the installation and removal of the plug in just a few simple steps without any additional tools. This innovative design not only improves work efficiency, but also reduces the requirements for professional skills, making network cabling and maintenance more convenient and popular. Excellent shielding performance to ensure signal stabilityIn network communications, electromagnetic interference (EMI) and radio frequency interference (RFI) are important factors that affect the stability and integrity of signal transmission. Tool-Free Shielding Crystal Plug effectively reduces the impact of these interferences on the signal by adopting advanced shielding technology. Its internal structure is reasonably designed to tightly wrap and isolate the signal line to prevent external electromagnetic fields from interfering with the signal. At the same time, the plug shell also uses highly conductive materials to further enhance the shielding effect. This excellent shielding performance ensures the stability and reliability of the signal during transmission, providing a strong guarantee for high-speed, high-quality network connections. Wide compatibility to adapt to a variety of application scenariosTool-Free Shielding Crystal Plug fully considers compatibility issues during design to ensure that it can adapt to a variety of network devices and cable types. Whether it is high-speed Ethernet standards such as CAT6A, CAT7 or CAT8, or network cables of different specifications and materials, Tool-Free Shielding Crystal Plug can provide stable and reliable connections. This wide compatibility enables the plug to be widely used in a variety of scenarios such as data centers, enterprise networks, and home networks to meet the diverse needs of different users. Durable and reliable, reducing maintenance costsTool-Free Shielding Crystal Plug has also put a lot of effort into material selection and manufacturing process. Its internal components are made of high-quality materials with good wear and corrosion resistance; the outer shell is made of strong and durable materials that can effectively resist external impact and extrusion. This durable and reliable design enables Tool-Free Shielding Crystal Plug to maintain stable performance during long-term use, reducing maintenance costs and time costs caused by failures.

  • 25 Apr’ 2024
    Shuaiye Communication Expands Global Reach with New Import-Export Rights

    With the acquisition of independent import and export rights, Cixi Shuaiye Communication Equipment Co., Ltd. is poised to extend its global market presence. This strategic move will enable the company to directly engage with international clients and stakeholders, streamlining its supply chain and bolstering its export portfolio.

  • 25 Apr’ 2024
    Cixi Shuaiye Unveils Cutting-Edge Cabling Solutions at International Tech Expo

    Cixi Shuaiye Communication Equipment Co., Ltd. took center stage at this year's International Tech Expo, introducing a series of innovative cabling products, including advanced Category 6a cables and optical fibers. These breakthroughs are expected to enhance data transmission efficiencies and open new avenues for technological partnerships.

  • 25 Apr’ 2024
    Cixi Shuaiye Communication Secures Prestigious ISO 9001:2000 Certification

    n a remarkable industry milestone, Cixi Shuaiye Communication Equipment Co., Ltd. has successfully passed the ISO 9001:2000 certification, reaffirming its commitment to quality management and customer satisfaction. This prestigious recognition marks the company's adherence to international standards, setting a new benchmark for excellence in the production of comprehensive cabling products.